Adagio

Tuya Smart 2 Way WiFi Energy Meter Bidirection 1 2 Channel with Clamp App Monitor Solar Produced and Consumed Power AC110V 240V

£48.49 £37.30 Save 23%
Tax included. Shipping calculated at checkout.
Bundle: 1 Channel-1CT
Ships From: CHINA

SPECIFICATIONS

Rated Voltage: 100-240V AC 50/60Hz

Measurable Current Range: 0.2A-80A

WiFi Frequency: 2.4GHZ (Not Support 5Ghz)

Ambient Temperature Range: -10°C ~ 55°C

APP: Smart Life / Tuya Smart

Brand Name: centechia

Compatibility: All Compatible

Model Number: 2 Way WiFi Energy Meter

State of Assembly: Ready-to-Go

Communication method: WI-FI

Origin: Mainland China

Certification: CE

Certification: RoHS

Choice: yes

semi_Choice: yes

NEW ARRIVAL Tuya WIFI Smart Dual Channel Energy Meter with 2 Clamp 80A - Available to Do Calibrate

2 Channels For Reverse and Forward direction

1 Channle or 2 Channels are available to Choose
And you can read from App for each Channel
- Real-time total power of 2 channels of reverse and forward direction
- Power for Channel A and B Separately(W)
- Current(mA)
- Voltage(V)
- Power factor, and Frequency(Hz)

Electricity Statistic for each channel in Forward and Reverse direction.
Hourly Elec. (KWh)
Daily Elec. (KWh)
Monthly Elec. (KWh)
-Yearly Elec. (KWh)

Technical data:
Rated Voltage:100-240V AC 50/60Hz
Measurable Current Range: 0.2A-80A
WiFi Frequency: 2.4GHZ (Not Support 5Ghz)
Ambient Temperature Range:-10°C ~ 55°C

Feature:

1.App can display Channel A and B Real-time power, current, voltage, power factor and frequency for Forward and Reverse direction clrealy
2.Electricity Statistic: Channel A , B Separately and Total daily monthly, yearly Reverse and Forward Direction
3.Automation.It allows to make a Scene for this device working with other tuya devices
4.Wiring Diagram. 1. To measure the power 'from Grid' and 'To Grid'.2. Measure the power consumption
5.Non-connect to Be Safe, Easy and Safe to Install.

Q&A

Q : After I configure it with App , why App shows 'shutdown' ?
A : Only if you put a device's wire (either live wire or neutral wire, not both) in the clamp, and turn on the device, then the clamp can sense the current, and App will show it is working

Q : I suppose P= U*I, why the value shows on App is not correct ?
A : Please consider the cos(Φ).
Because As resistances do not produce any phasor difference (phase shift) between voltage and current waveforms, all the useful power is delivered directly to the resistance and converted to heat, light and work. Then the power consumed by a resistance is real power which is fundamentally the circuits average power.
To find the corresponding value of the real power the rms voltage and current values are multiplied by the cosine of the phase angle, Φ as shown.
Real Power P = I2R = V*I*cos(Φ) Watts, (W)


Bundle: 1 Channel-1CT
Ships From: CHINA